PARISON CONTROLLER
moog
Moog Italiana srl - Bergamo MAN145-UM-D01A-EN 27
Figure 28
If the function Free Profiles Assignment is enabled (full edit mode; see Setup Machine Page) it is possible to
assign to each head anyone of the 8 profiles available.
The 8 profiles can be displayed, modified and copied (if they are not already assigned to some head) in the Edit
page. In this page it is possible to know which profile each regulator is using.
2.5.9 Control Update Rate.
The close loop sampling time is normally 2 ms.
In continuous extrusion with only one head the control is faster (only 1 ms sampling time).