PARISON CONTROLLER
moog
Moog Italiana srl - Bergamo MAN145-UM-D01A-EN 17
2.4.5 Other function keys possibilities.
by pressing the key DEL it's possible to remove a master on the profile, in correspondence to the cursor
point.
by pressing the function key programmed as Toggle marker (F2) it's possible to add or remove a marker
on the profile in correspondence with the cursor point. By the function key DEL it's possible to remove a
marker.
If a master and a marker are both on the same point, press the key DEL to remove the marker as first.
by pressing the function key programmed as Select interpolation (F4) it's possible to change the type of
the interpolation area between two masters, the choice selection is made among Bezier curves, linear, flat,
parabolic 1, parabolic 2.
by the function key programmed as Clear (F3) it's possible to completely delete the current profile. The
PLC profile will be updated only when the operation is confirmed by pressing the Set Key.
When the serial marker panel is visible (set the parameter to ON in Setup Machine Page), the following operations
are possible:
modify the serial marker using F5 to set Vertical arrows to Drag SM and F6 to select Knob as Setup SM.
The SM can be dragged using the arrows.
the status of the serial marker can be switched ON and OFF using the knob or
+
and - keys.
2.5 Functionality.
2.5.1 Safe Condition.
Necessary conditions to start issuing a new profile are:
Temperature Ok ON
Emergencies ON
Alarm OFF
machine in automatic ON
Purge OFF
Tooling OFF
The digital input machine in automatic has to be ON during the normal work and has to be OFF
during the machine configuration. (Machine type selection, number of heads selection, number of
point selection, number of extruder selection, output command type selection, heads and
accumulator calibration and die type selection)
2.5.2 Language packages.
PARISON CONTROLLER is supplied with a language package (application rev. IMI220145D001.X.XX). It is
possible to choose among the following languages:
English, Italian, German, French, Spanish, Portuguese, Danish, Russian, Turkish, Greek, Chinese and Japanese.

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Moog IMI220-145D001 and is the answer not in the manual?

Moog IMI220-145D001 Specifications

General IconGeneral
BrandMoog
ModelIMI220-145D001
CategoryController
LanguageEnglish

Related product manuals