PARISON CONTROLLER
moog
104 MAN145-UM-D01A-EN Moog Italiana srl - Bergamo
4.18.2 List of the alarms.
[001] PARISON CONTROLLER not Configured.
Active if in the Setup Machine Page there is nothing selected in "Function of machine." In practice
to the startup, when the machine is not configured.
[002] Head 1 not calibrated.
Active if without feedback actuator the limits of calibration are equal (V. Up and V. Down at Setup 1
Head 1 Page).
[003] Head 2 not calibrated.
Active if without feedback actuator the limits of calibration are equal (V. Up and V. Down at Setup 1
Head 2 Page).
[004] Head 3 not calibrated.
Active if without feedback actuator the limits of calibration are equal (V. Up and V. Down at Setup 1
Head 3 Page).
[005] Head 4 not calibrated.
Active if without feedback actuator the limits of calibration are equal (V. Up and V. Down at Setup 1
Head 4 Page).
[006] Accumulator not calibrated.
Active if in Setup Machine Page Function of the machine is set in Accumulator Position and the
limits of calibration are equal (V. Full and V. Empty at Setup Accumulator Page).
[007] Extruder 1 not calibrated.
Active if in Extruder setup 1 Page (if Extruder 1 is present in Setup Machine Page) with Analogical
Extruder Type:
the limits of input calibration are equal (Minimum Voltage and Maximum Voltage);
the Velocity with V max is 0 rpm;
the Vel. Min Planned and Vel. Max Planned are equal;
the Maximum Velocity (output calibration) is 0 mV;
the Voltage/Current with max Velocity is 0 mV.
With Digital Extruder Type:
the Maximum Duration Inc/Dec is 0 ms.
[008] Extruder 2 not calibrated.
Active if in Extruder setup 2 Page (if Extruder 2 is present in Setup Machine Page) with Analogical
Extruder Type:
the limits of input calibration are equal (Minimum Voltage and Maximum Voltage);
the Velocity with V max is 0 rpm;
the Vel. Min Planned and Vel. Max Planned are equal;
the Maximum Velocity (output calibration) is 0 mV;
the Voltage/Current with max Velocity is 0 mV.
With Digital Extruder Type:
the Maximum Duration Inc/Dec is 0 ms.
[021] Temperature not OK.
Active if the Digital Input number 10 Temperature OK is OFF.