PARISON CONTROLLER
moog
Moog Italiana srl - Bergamo MAN145-UM-D01A-EN 105
[022] Emergency not OK.
Active if the Digital Input number 11 Emergency is OFF.
[023] Machine in alarm.
Active if the Digital Input number 12 Presence alarm in machine is ON.
[024] Completed production.
Active when in Production Page (if enable) the Good Pieces are equal to Pieces to be produced
(Different to 0).
[025] Head 1 not worked.
Active when in Setup 1 Head 1 Page the Operation is different to Work (Open Loop or Manual
Calibration or Automatic Calibration).
[026] Head 2 not worked.
Active when in Setup 1 Head 2 Page (if Head 2 is enable) the Operation is different to Work (Open
Loop or Manual Calibration or Automatic Calibration).
[027] Head 3 not worked.
Active when in Setup 1 Head 3 Page (if Head 3 is enable) the Operation is different to Work (Open
Loop or Manual Calibration or Automatic Calibration).
[028] Head 4 not worked.
Active when in Setup 1 Head 4 Page (if Head 4 is enable) the Operation is different to Work (Open
Loop or Manual Calibration or Automatic Calibration).
[029] Accumulator not worked.
Active when in Setup Accumulator (if Accumulator is enable) the Operation is different to Work (Open
Loop or Calibration).
[030] Purge general enable.
Not managed.
[031] Purge external 1 enable.
Active if the Digital Input number 4 Purge Group 1 is ON.
[032] Purge external 2 enable.
Active if the Digital Input number 8 Purge Group 2 is ON.
[033] Purge head 1 enable.
Active if the single Purge on the Work Head 1 Page is enable. It is active even used the Fast Access
Key on the front panel (All the Head).
[034] Purge head 2 enable.
Active if the single Purge on the Work Head 2 Page is enable. It is active even used the Fast Access
Key on the front panel (All the Head).
[035] Purge head 3 enable.
Active if the single Purge on the Work Head 3 Page is enable. It is active even used the Fast Access
Key on the front panel (All the Head).