EasyManua.ls Logo

Moog IMI220-145D001 - Page 106

Moog IMI220-145D001
113 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
PARISON CONTROLLER
moog
106 MAN145-UM-D01A-EN Moog Italiana srl - Bergamo
[036] Purge head 4 enable.
Active if the single Purge on the Work Head 4 Page is enable. It is active even used the Fast Access
Key on the front panel (All the Head).
[037] Master Tooling active.
Not managed.
[038] Tooling head 1 active.
Active if the single Tooling on the Work Head 1 Page is enable. It is active even used the Fast Access
Key on the front panel (All the Head).
[039] Tooling head 2 active.
Active if the single Tooling on the Work Head 2 Page is enable. It is active even used the Fast Access
Key on the front panel (All the Head).
[040] Tooling head 3 active.
Active if the single Tooling on the Work Head 3 Page is enable. It is active even used the Fast Access
Key on the front panel (All the Head).
[041] Tooling head 4 active.
Active if the single Tooling on the Work Head 4 Page is enable. It is active even used the Fast Access
Key on the front panel (All the Head).
[042] Feedback error channel 1.
Active if:
the analog input 1 is greater or equal 10000 mV and Feedback Actuator on Setup 1 Head 1 Page is
OFF;
the analog input 1 is greater or equal 10000 mV and Feedback Actuator on Setup 1 Head 1 Page is
ON and contemporarily Show Feedback on Work Head 1 Page is ON.
[043] Feedback error channel 2.
Active if:
the analog input 2 is greater or equal 10000 mV and Feedback Actuator on Setup 1 Head 2 Page is
OFF;
the analog input 2 is greater or equal 10000 mV and Feedback Actuator on Setup 1 Head 2 Page is
ON and contemporarily Show Feedback on Work Head 2 Page is ON.
[044] Feedback error channel 3.
Active if:
the analog input 3 is greater or equal 10000 mV and Feedback Actuator on Setup 1 Head 3 Page is
OFF;
the analog input 2 is greater or equal 10000 mV and Feedback Actuator on Setup 1 Head 3 Page is
ON and contemporarily Show Feedback on Work Head 3 Page is ON.
[045] Feedback error channel 4.
Active if:
the analog input 4 is greater or equal 10000 mV and Feedback Actuator on Setup 1 Head 4 Page is
OFF;
the analog input 2 is greater or equal 10000 mV and Feedback Actuator on Setup 1 Head 4 Page is
ON and contemporarily Show Feedback on Work Head 4 Page is ON.