PARISON CONTROLLER
moog
86 MAN145-UM-D01A-EN Moog Italiana srl - Bergamo
4.10.1 Extruder command.
Figure 87
Enable extruder: enable the output
command to control the extruder velocity.
The command velocity goes to 0 (if Enable
extruder is NO) or to the velocity setpoint by
a ramp.
Velocity setpoint: insert the velocity
setpoint. (visible with “Analog extruder”).
Minimum correction: with the velocity control if the error is lower to the planned minimum one (in point) it is
possible to apply a minimum correction however (in rpm).
Command velocity: Output command velocity. (visible with “Analogical extruder”).
Real velocity: Show the real velocity in rpm. (visible with “Analogical extruder”).
Point for control: (if enabled “Control length profile”) Show the point for control.
Point: (if enabled “Control length profile”) Current point from select head or point of accumulator extrusion.
Last correction: (with “Control length profile”) increment or decrement value with Analogical extruder.(rpm).
Last correction: (with “Control length profile”) increment or decrement value with Digital extruder.(ms)
4.10.2 Velocity increment and decrement.
Velocity increment: (visible with “Digital extruder”) show the digital
output for increment.
Velocity decrement: (visible with “Digital extruder”) show the
digital output for decrement.
4.10.3 Function Keys.
SETUP: (yellow) Disable. (black) Enter in the setup Extruder.
INC: (visible with “Digital extruder”) Velocity increment key.
DEC: (visible with “Digital extruder”) Velocity decrement key.
NEXT: Enter the next Setup page.
MENU 1: Go to main menu 1.

Table of Contents