9-34 Manual # 42-02-2223
Reference
LP22
Reference
Direction
Not yet implemented
Up
Down
Up + Down
0
1
2
--Up
LP23
Reference
Speed
Not yet implemented
-
0-1600 ft/min 0
LX Special Functions Parameters
LX01 Auto Reset - - 0-10 - 5
LX02
Switching
Frequency
8 kHz
12 kHz
16 kHz
0
1
2
-kHz8
LX06 Function Test
Off
Fans On
0
1
--Off
LX08
Phase Current
Check
Mag. Current Check
Phase Current Check
0
1
--
Phase Cur-
rent Check
LX09 Watchdog Time - - Off (0)-10.00 sec 1.00
LX10 EdOH Function
Off
On
0
1
--Off
LX11
Reference
Splitting
- - 0-127 msec 0
LX12 Baud Rate
1200 bps
2400 bps
4800 bps
9600 bps
19200 bps
38400 bps
55500 bps
115200 bps
0
1
2
3
4
5
6
7
- bps 38400
LX13
Speed
Following Error
Warning - Digital Output
On with Error % Contract Spd
On with Error % Command
Speed
0
1
2
--
Warning-
Digital
Output
1
LX14
Speed
Difference
--1-50%10
LX15
Speed for
Pre-Opening
-
-
1-100 ft/min 59
LX16
Decel
Confirmation
Speed
-
-
0-1600 ft/min 0
LX17 ETS Speed - - 0-1600 ft/min 0
LX18
Braking
Resistance
-
-
0.0-200.0 Ohm 0.0
LX 21
Unintended
Motion
Off
On
0
1
--Off
LX22
Encoder
Deviation Value
-
0-25000 - 5,000
LX23
Encoder
Deviation
Enable
OFF
On with Error
0
1
--Off
Table 9.5 TORQMAX F5 Drive, v3.21 LCD Parameter Settings
Para. Name Setting Num Range Units Default
Field
Setting

Table of Contents