9-33
TORQMAX F5 Drive v3.xx Parameters Table
iControl AC
9
LT12
Current Hold
Time
- - 0.00-2.00 sec 0.50
0.0
LT13
Current Ramp
Down Time
- - 0.10-0.50 sec 0.30
LP Positioning Parameters
LP01
Positioning
Control
Off
Posi One Floor
Learn Slowdown
Position Value Reset
0
1
2
3
Off
LP02
Minimum Slow-
down Distance
- 0.00-600.00 in 0.00
LP03
High Speed
Slowdown Dist.
0.00-600.00 in 0.00
LP04
Short Floor
Slowdown
Distance
0.00-600.00 in 0.00
LP05
Correction
Distance
- - 0.00-25.00 in 0.00
LP06
Scaling Incre-
ments High
- - 0-9999 - 0
LP07
Scaling Incre-
ments Low
- - 0-9999 - 0
LP08
Scaling
Distance
0.00-600.00 in 0.00
LP10 Floor Number Not yet implemented 1-30 - 1
LP11 Floor Enable
Not yet implemented
Disabled
Enabled
0
1
--Disabled
LP12 Floor Position Not yet implemented 0.0-6553.5 in 0.0
LP13
Correction
Distance Up
Not yet implemented
0.0-25.0 in 0.0
LP14
Correction
Distance Down
Not yet implemented
0.0-25.0 in 0.0
LP15
Max Floor
Speed
Not yet implemented
-
0-1600 ft/min 0
LP16 Floor Label Not yet implemented - 1-65535 - 1
LP18
Leveling
Distance
Not yet implemented
-
0.0-12.0 in 0.0
LP19
Re-leveling
Distance
Not yet implemented
-
0.0-3.0 in 0.0
LP20
Position
Feedback
Source
Not yet implemented
Motor Encoder
Absolute Hoistway Encoder
Serial Bus
0
1
2
--
Motor
Encoder
LP21 Reference Floor Not yet implemented - 0-30 - 1
Table 9.5 TORQMAX F5 Drive, v3.21 LCD Parameter Settings
Para. Name Setting Num Range Units Default
Field
Setting