9-43
TORQMAX F5 Drive v3.xx Parameters Table
iControl AC
9
FB37 PDI4 Data - -
80000000h -
7FFFFFFFh
--
FB50
Temp DIN Com
Err. Cnt.
- - 0-65535 - 0
FB51
Temp DIN Com
Err. Serv.
- - 0-128 - 0
FB52
Temp DIN Com
Err. Ack.
--
-32768 -
32768
-0
FB53
Temp DIN Com
Err. Val.
--
-2147483647 -
2147483647
-0
FB54 RS485 Mode
Full Duplex
Half Duplex
0
1
0-1 - Full Duplex
FB55 Software Filter - - 0-255 ms 0: Off
TS Terminal Slowdown Parameters
TS01 NTSD Mode
External
Threshold 1
Threshold 2, Binary Encoded
Threshold 3, Binary Encoded
One switch per threshold
0
1
2
3
4
0External
TS02
NTSD Target
Speed
0-1600 ft/min 0
TS03
NTSD Speed 1
Up
- - 0-1600 ft/min 0
TS04
NTSD Speed 2
Up
- - 0-1600 ft/min 0
TS05
NTSD Speed 3
Up
- - 0-1600 ft/min 0
TS06
NTSD Speed 1
Down
- - 0-1600 ft/min 0
TS07
NTSD Speed 2
Down
- - 0-1600 ft/min 0
TS08
NTSD Speed 3
Down
- - 0-1600 ft/min
Table 9.5 TORQMAX F5 Drive, v3.21 LCD Parameter Settings
Para. Name Setting Num Range Units Default
Field
Setting