9-51
Magnetek HPV900 Series 2 Parameters Quick Ref-
iControl AC
9
Log In 3 TB1-3 Terminal 3 Selection - - FAULT
RESET
FAULT
RESET
Log In 4 TB1-4 Terminal 4 Selection - - FAULT
RESET
NO
FUNCTION
Log In 5 TB1-5 Terminal 5 Selection - - STEP REF
B0
NO
FUNCTION
Log In 6 TB1-6 Terminal 6 Selection - - STEP REF
B1
NO
FUNCTION
Log In 7 TB1-7 Terminal 7 Selection - - STEP REF
B2
NO
FUNCTION
Log In 8 TB1-8 Terminal 8 Selection - - STEP REF
B3
NO
FUNCTION
Log In 9 TB1-9 Terminal 9 Selection - - S-CURVE
SEL 0
NO
FUNCTION
C3 Logic Outputs
Log Out 1 tb1-14 Terminal 14 Selection - - SPEED
DEV LOW
NO
FUNCTION
Log Out 2 tb1-15 Terminal 15 Selection - - RUN COM-
MAND
NO
FUNCTION
Log Out 3 tb1-16 Terminal 16 Selection - -
MTR
OVERLOAD
NO
FUNCTION
Log Out 4 tb1-17 Terminal 17 Selection - - ENCODER
FAULT
NO
FUNCTION
Relay Coil 1 Relay 1 Function Selection - - READY TO
RUN
READY
TO RUN
Relay Coil 2 Relay 2 Function Selection - - SPEED
REG RLS
SPEED
REG RLS
C4 Analog Outputs
Ana Out 1 tb1-33 Terminal 33 Selection - - SPEED
CMD
Ana Out 2 tb1-35 Terminal 35 Selection - - SPEED
FEEDBK
SPEED
FEEDBK
Utility U0
U1 Password
Password - - 000000
U2 Hidden Items
Enable or disable hidden parameters
Enable Disable
-- ENABLE
U3 Unit
Unit for parameters
English Metric
-- ENGLISH
U4 Overspeed Test
Allows overspeed test during inspection
Yes No
-- No
U5 Restore Dflts
Reset all parameters to default values
U6 Drive Info
Drive information:
Drive Version:
Boot Version:
Cube ID:
Drive Type:
U7 HEX Monitor
Hex Monitor
Table 9.7 Magnetek AC Drive Parameters Table
#
Operator
Display
Parameter Description Unit
Setting
Range
MCE
Defaults
Field
Setting