EasyManua.ls Logo

Motion Control Engineering Nidec iControl - Page 416

Default Icon
453 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
9-51
Magnetek HPV900 Series 2 Parameters Quick Ref-
iControl AC
9
Log In 3 TB1-3 Terminal 3 Selection - - FAULT
RESET
FAULT
RESET
Log In 4 TB1-4 Terminal 4 Selection - - FAULT
RESET
NO
FUNCTION
Log In 5 TB1-5 Terminal 5 Selection - - STEP REF
B0
NO
FUNCTION
Log In 6 TB1-6 Terminal 6 Selection - - STEP REF
B1
NO
FUNCTION
Log In 7 TB1-7 Terminal 7 Selection - - STEP REF
B2
NO
FUNCTION
Log In 8 TB1-8 Terminal 8 Selection - - STEP REF
B3
NO
FUNCTION
Log In 9 TB1-9 Terminal 9 Selection - - S-CURVE
SEL 0
NO
FUNCTION
C3 Logic Outputs
Log Out 1 tb1-14 Terminal 14 Selection - - SPEED
DEV LOW
NO
FUNCTION
Log Out 2 tb1-15 Terminal 15 Selection - - RUN COM-
MAND
NO
FUNCTION
Log Out 3 tb1-16 Terminal 16 Selection - -
MTR
OVERLOAD
NO
FUNCTION
Log Out 4 tb1-17 Terminal 17 Selection - - ENCODER
FAULT
NO
FUNCTION
Relay Coil 1 Relay 1 Function Selection - - READY TO
RUN
READY
TO RUN
Relay Coil 2 Relay 2 Function Selection - - SPEED
REG RLS
SPEED
REG RLS
C4 Analog Outputs
Ana Out 1 tb1-33 Terminal 33 Selection - - SPEED
CMD
Ana Out 2 tb1-35 Terminal 35 Selection - - SPEED
FEEDBK
SPEED
FEEDBK
Utility U0
U1 Password
Password - - 000000
U2 Hidden Items
Enable or disable hidden parameters
Enable Disable
-- ENABLE
U3 Unit
Unit for parameters
English Metric
-- ENGLISH
U4 Overspeed Test
Allows overspeed test during inspection
Yes No
-- No
U5 Restore Dflts
Reset all parameters to default values
U6 Drive Info
Drive information:
Drive Version:
Boot Version:
Cube ID:
Drive Type:
U7 HEX Monitor
Hex Monitor
Table 9.7 Magnetek AC Drive Parameters Table
#
Operator
Display
Parameter Description Unit
Setting
Range
MCE
Defaults
Field
Setting

Table of Contents