6802800U74-AN
Chapter 6: Configuration and Testing
• pm_config br 1 dpm 1
• pm_config br 2 dpm 1
3 To configure the DPM and ATCC mapping to BR, type pm_config [-?].
4 To configure the ATCC (cavity) to BR mapping, type br <br> atcc <atcc> cav
<cavity>.
5 To configure the DPM to BR mapping, type br <br> dpm <dpm>.
6 To clear the mapping for a given BR, type -invalidate <br>.
7 To clear all mapping, type -invalidate.
8 To print all mapping, type -print.
6.5.4
Station Verification Procedures
Station verification procedures cover methods to verify transmit and receive operations after the Base
Radio module installation or replacement. Each section contains the equipment setup and the
procedure.
6.5.4.1
Verifying the Base Radio Software Revision
Procedure:
1 Log on to the Base Radio Application using the procedure Logging on to the Base Radio
Application through Serial Connection on page 224.
2 Enter the command ver to check current versions of your Base Radio applications.
3 Log on to the Test Application of the Base Radio using procedure Logging on to the Test
Application on page 225.
4 Collect revision numbers from the BR by typing: fv -oplatform.
5 Note down the test application software version and then see the System Software Release
Note for the correct software version number.
6 To exit BR Test Application mode, reset the BR using the following command from the MMI:
reset -oplatform
7 If the software version numbers do not match, update the Test Application. For BR-Arch-1, see
Upgrading the Base Radio Test Application Software in BR-Arch-1 Architecture (Optional) on
page 244.
Base Radios in BR-Arch-2 architecture do not require manual updates. If you want to update the
software in BR-Arch-2 Base Radios for testing purposes, see Upgrading the Base Radio
Software in BR-Arch-2 Architecture (Optional) on page 244.
NOTICE: BR-Arch-2 Base Radio software updates can be performed only by authorized
technical personnel.