5. Names and Functions of Components
Chapter 1 General Description
5.6.8
Location LED
The failed FRU can be identified in detail by viewing Location LED together with FRU LED. (For FRU LED, see
Chapter 1 (1.6.5 FRU (CPU, MEM, PCI, PSU/FAN, NEXT, MISC) LED).) Location LED is composed of 8 LEDs.
If any of 8 LEDs are lit, the relevant FRU LED (one of CPU, MEM, PCI, PSU/FAN, MISC) also goes on at the
same time.
The following table lists Location LED patterns and their explanation.
Lighting FRU
LED
Location LED LED pattern
Explanation (○: Off/ ●: On)
CPU
On (green) Indicate the failed CPU number.
: CPU#1, : CPU#2, : CPU#3, : CPU#4
MEM
On (green) Indicates failure occurred on DIMM, PAIR, or MR.
: DIMM failed, : PAIR failed, : MR failed
On (green) At MR failure, indicates the failed MR number.
: MR#1, : MR#2, : MR#3, : MR#4, :
MR#5, : MR#6, : MR#7, : MR#8
On (green) At DIMM failure, indicates the failed DIMM number.
: DIMM#1, : DIMM #2, : DIMM #3,
: DIMM #4, : DIMM #5, : DIMM #6,
: DIMM #7, : DIMM #8
At PAIR failure, indicates the failed PAIR number.
: PAIR #1, : PAIR #2, : PAIR #3,
: PAIR #4, Unused when failure occurred on MR().
PCI
On (green) Indicates the PCI slot number.
: Slot #1, : Slot #2,
: Slot #3, : Slot #4,
: Slot #5, : Slot #6,
: Slot #7, : Slot #8,
: Slot #9, : Slot #10,
: Slot #11, : Slot #12,
: Slot #13, : Slot #14,
: Slot #15, : Slot #16
PSU/FAN On (green) Indicates that PSU (power supply unit) or SFM (cooling fan unit) is
failed.
: PSU, :SFM
On (green) At PSU failure, indicates the PSU (power supply unit) number.
: PSU#1, : PSU#2, : PSU#3, : PSU#4
At SFM failure, indicates that SFM (cooling fan unit) number.
: SFM#1, : SFM#2
MISC On (green) Indicates the failed FRU other than above.
: BM
: Battery (on motherboard)
: FDM, : DVD
: MGB#1, : MGB#2
: MGB#1 Battery
: MGB#2 Battery
: SPI Mezz#1
: SPI Mezz#2,
: RCB,
: Cannot identify the failed FRU.
0
1
2
7
6
5
4
7
6
7
6
3
5
4
7
6
7
6
5
4
3
0
1
2
5
4
Express5800/A1040b, A2040b, A2020b, A2010b User's Guide