1. Installing / Removing Internal Options
Chapter 2 Preparations
5. If you use the server with hard disk drive
being removed, mount dummy trays in the
vacant slot.
Note
Do not hold the handle to pull the hard disk drive out from the slot. Doing so may damage
the handle.
6. Run BIOS SETUP utility, and then specify the boot order from the Boot menu. For details about the
Boot menu, refer to Chapter 2 (1. System BIOS) in "Maintenance Guide".
Tips
The saved boot order is cleared when a hard disk drive is removed.
7. Refer to Steps 6 to 10 in Chapter 2 (1.4 Overview of Installation and Removal) to check if work is
successfully completed.
8. Cancel the maintenance mode you have set in Step 1. (See Chapter 3 (7.7.1 BMC (7) Extended
Functionality) for how to cancel the maintenance mode. If the UID LED is on, turn off the UID LED using
UID switch.
1.8.3
Use of Internal hard disk drives in the RAID System
This section describes how to use the internal hard disk drives in the RAID System.
Important
If you use hard disk drives in the RAID System or change the RAID level, the hard
disk drives are initialized. If the ha
rd disk drive contains valuable data, be sure to
backup the hard disk drive before installing the RAID Controller and configuring the
RAID System.
Note
In the RAID System, use hard disk drives that have the same specifications (
capacity,
rotational speed, and standard) for each Disk Array.
Tips
Logical Drives can be created even with only one Physical Device.