EasyManua.ls Logo

NEC express5800 A2010b - Displaying Specified Sensor

NEC express5800 A2010b
491 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
9. WS-Management
Chapter 3 Setup
9.3.2
Displaying Specified Sensor
You can display the sensor data by specifying sensor number.
Run the following command to display the sensor data of sensor number 0 that has threshold value by using
WinRM.
winrm get
"http://schemas.dmtf.org/wbem/wscim/1/cim-schema/2/CIM_NumericSensor?SystemCreationClassNam
e=CIM_ComputerSystem+CreationClassName=CIM_NumericSensor+SystemName=Unknown.IPMI BMC
DeviceID.5B+DeviceID=1.0.0.32.1.99" -r:PROTOCOL://IP_ADDRESS/wsman -username:USERNAME
-password:PASSWORD -auth:basic -encoding:utf-8 -skipCAcheck -skipCNcheck -skipRevocationcheck
Run the following command to display the sensor data of sensor number 1 that does not have threshold value
by using WinRM.
winrm get
"http://schemas.dmtf.org/wbem/wscim/1/cim-schema/2/CIM_Sensor?SystemCreationClassName=CIM_C
omputerSystem+CreationClassName=CIM_Sensor+SystemName=Unknown.IPMI BMC DeviceID.5B+DeviceID=
2.1.0.32.b.0" -r:PROTOCOL://IP_ADDRESS/wsman -username:USERNAME -password:PASSWORD -auth:basic
-encoding:utf-8 -skipCAcheck -skipCNcheck -skipRevocationcheck
Important
Specify the IP address of EXPRESSSCOPE Engine SP3 for "IP_ADDRESS", and
login user name and login password for ”USERNAME/PASSWORD”
in the
example.
Specify http or https for "PROTOCOL" in the example.
Specify ”Unknown.IPMI BMC DeviceID.5B” for <SystemName>.