7. Using Remote Management
Chapter 3 Setup
Item name
Setup value (*1)
Default value (*2)
Alert (*3)
Enable or disable SNMP alert.
Disable
Computer Name (*4)(*5)
Specify the host name used for SNMP alert.
Blank
Community Name (*4)
Specify the community name used for
SNMP alert.
public
Alert Acknowledge (*4)(*6)
Select Enable or Disable to acknowledge
response from destination.
Enable
Alert Process (*4) Specify the alert destination.
One Alert Receiver
All Alert Receiver
One Alert Receiver
Retry Count (*4)
Specify the number of retries to send an
alert. Allowable range is between 0 and 7.
3
Timeout (sec) (*4)
Specify the timeout time to send an alert.
Allowable range is between 3 and 30.
6
Alert Receiver 1 (*4)(*7)
IP Address
Specify the IP address of destination. (*8)
0.0.0.0
Alert Receiver 2 (*4)(*7)
IP Address
Specify the IP address of destination. (*8)
0.0.0.0
Alert Receiver 3 (*4)(*7)
IP Address
Specify the IP address of destination. (*8)
0.0.0.0
Alert Level (*4)
Alert Level
Specify the type of event to be sent.
Critical
Critical, Non-critical
Critical, Non-critical, Information
Separate Setting (*9)
Critical, Non-critical
(*1) Addresses and character strings are example.
(*2) Factory-set value.
(*3) Displayed when [Configuration] [Miscellaneous] "PEF(Platform Event Filtering)" is set to "Enable".
(*4) Displayed when Alert is set to "Enable".
(*5) Computer name must be specified with 1-byte alphanumeric.
(*6) Set to "Enable" when NEC ESMPRO Manager is used for management.
(*7) At least one destination must be enabled.
(*8) When the [Alert Test] button is pressed, a pseudo event to the specified destination.
(*9) You can set an alert level individually for each sensor type.