CHAPTER 3 SYSTEM DATA PROGRAMMING
– 133 – NWA-008853-001 Rev.3.0
97ch3001.fm
DESCRIPTION DATA
When using the programmable PAD (CM35
Y=19, 2nd Data=0-3), assign the PAD data.
(1)
(2)
50-65: See tables below.
00-15: See tables below.
D
CM42
[Australia/New Zealand]
T/R: Transmit/Receive
+: Gain
–: Loss
PAD DATA PATTERNS
CONNECTING
PATTERNS (A-B)
CM35 Y=19
2ND DATA=0
CM35 Y=19
2ND DATA=1
CM35 Y=19
2ND DATA=2
CM35 Y=19
2ND DATA=3
50
65
50 54 58 62 STA-ODT/LDT
51 55 59 63 TONE-ODT/LDT
52 56 60 64 COT/DID/LDT/
ODT (2W E&M)/IPT-
ODT/LDT
53 57 61 65 ODT (4W E&M)/DTI/
BRT/PRT/CCT/Virtual
IPT/CFTC-ODT/LDT
PATTERNS
2ND DATA
PAD DATA OF B TRUNK (T/R) [dB]
ODT LDT
00
15
00 0/0 0/+6
01 –3/–3 0/+6
02 –8/–8 –6/+6
03 –6/–6 0/0
04 0/0 0/+6
05 0/–6 0/0
06 –6/0 0/0
07 0/0 0/0
08
15
Not Used
~ ~
~
PATTERNS
1ST DATA
E
ANALOG CCIS PROGRAMMING