NMC-PRO Installation Manual
105Page
SETUP MENU
Use the left/right arrow keys to increase/decrease values.
For temperature and humidity sensors calibration can be done using reference temperature and humidity
sensors.
Wind direction sensor should be calibrated so that the value indicated by the NMC-Pro fits the actual direction
pointed by the wind direction sensor.
The radiation sensor factor should be set as indicated in the calibration sticker supplied with the sensor. The
radiation offset should be set to 17 unless specified otherwise.
See NMC-Pro Irrigation Part 2 > Sensor specifications > Weather sensor specifications for additional
information.
10.8 Sensors Logging
The Sensors Logging screen allows you to define which sensors should be logged.
To select an item move the cursor using the arrow keys and mark it using the ‘+/-‘ key. Selected items are marked with
.
Note: When you change the sensors logging setup, the sensors history table resets and starts over; all sensors
data accumulated on the controller is lost.
10.9 Write to Data Plug
Use a data-plug to save controller settings and restore them when needed. Plug the data-plug into the NMC-Pro data-
plug socket (see Figure 98). The data-plug is symmetric so it can be plugged in both directions.
Enter the WRITE TO DATA PLUG screen and confirm your choice.
Note: When writing to a data-plug, old data on the data-plug will be overwritten.

Table of Contents

Other manuals for Netafim nmc-pro

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Netafim nmc-pro and is the answer not in the manual?

Netafim nmc-pro Specifications

General IconGeneral
BrandNetafim
Modelnmc-pro
CategoryController
LanguageEnglish

Related product manuals