EasyManuals Logo

Netafim nmc-pro Installation Guide

Netafim nmc-pro
167 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #70 background imageLoading...
Page #70 background image
NMC-PRO Installation Manual
70Page
PROGRAM MENU
5. Go to Test > Analog Sensor.
6. Test the sensor values.
5.6 Agitator
The agitator is used to mix the fertilizers and acid in the storage tanks in order to prevent the occurrence of sediment.
Dosing Active: Definition of the On and Off times of the agitator when dosing is taking place:
On: Define the required mixing time.
Off: Define the required time between mixing.
Dosing Not Active: definition of the On and Off times of the agitator when dosing is not taking place:
On: Define the required mixing time.
Off: Define the required time between mixing.
ANALOG SENSOR
No.
Type
Value
1
NetSense
10.784
2
ECh20
19.355
3
<NONE>
0.000
4
<NONE>
0.000
ANALOG CONVERSION TABLE
Num.
Sensor Type
Min Value
Max Value
1
NetSense
7.0
45.0
2
ECh20
0.0
60.0