NMC-PRO Installation Manual
89Page
HISTORY MENU
8.6 Irrigation Accumulation
The Irrigation Accumulation table allows you to accumulate water and dosing quantities for the required periods. The
accumulation of each valve can be reset separately in the Accumulation Reset table.
To toggle the view between quantities and time, press the ‘+/- key. Water quantity is measured in cubic meter or
gallons; dosing quantity is measured in liters or gallons.
8.7 AUX Meter Accumulation
The Auxiliary Meter Accumulation table allows you to accumulate quantities from meters that do not have designated
software, for example, in order to measure the drain water quantity or to measure the cooling system’s consumption.
Note: These water meters are accumulators only and are not a part of the irrigation control.
The quantities displayed are in liters (gallons) up to 9999.999. To reset an auxiliary meter refer to the Accumulation
Reset table below.
8.8 Accumulation Reset
To reset accumulation of an individual valve or of all valves press the ENTER key, choose the relevant option using
the arrow keys and confirm by pressing the ENTER key.

Table of Contents

Other manuals for Netafim nmc-pro

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Netafim nmc-pro and is the answer not in the manual?

Netafim nmc-pro Specifications

General IconGeneral
BrandNetafim
Modelnmc-pro
CategoryController
LanguageEnglish

Related product manuals