OPERATING MANUAL
4-6
21833-3.4
NORMARC 7013
INSTRUMENT LANDING SYSTEM
Tower Equipment ©1999 Navia Aviation AS
For maintenance purposes, an interlock override function has been implemented. This func-
tion makes it possible to operate the ILS locally in manual mode with an active interlock sig-
nal. To activate the interlock override function the following conditions must be met:
LOCAL/REMOTE switch must be in LOCAL position,
AUTO/MANUAL switch must be in MANUAL position and
INTERLOCK OVERRIDE switchlock must be set in horizontal position.
The remote control will always be set in ALARM state when the interlock override function is
activated.