Using the Console Interface
893-00992-E
3-81
The write threshold is reset when either of the following occurs:
• The BayStack 350 switch is reset.
• The firmware determines that compression is required for maintenance of the
event log’s flash memory.
Reset
The Reset command (accessed from the main menu) allows you to reset the
BayStack 350 switch without erasing any configured switch parameters.
Resetting the switch takes approximately five seconds to complete. During this
time, the switch initiates a self-test that comprises various diagnostic routines and
subtests. The LEDs display various patterns to indicate that the subtests are in
progress.
The results of the self-test are displayed briefly in the Self-Test screen
(Figure 3-37
), which is followed by the CI screens.
Figure 3-37. Self-Test screen after resetting the switch
Note:
The Self-Test screen remains displayed only if the self-test detects a
fatal error.
BayStack Model 350T Self-Test
ASIC addressing test ... Pass
ASIC buffer RAM test ... Pass
Physical layer test ... Pass
Port internal loopback test ... Pass
Self-test complete.