45584901TH Rev.1
10-4 /
Oki Data CONFIDENTIAL
5.BKCTRsignal,MNCTRsignal,FLCTRsignal(outputsignals)
These signals become“Low” (ON) synchronizing with the CTRON signal according to the
copying mode used. The pulse width corresponds to the fixed time. Though the CTRON
signalissetto“Doublecount”,theyarenotoutputtedsynchronizingwiththesecondcount
signal.
6.SIZE3,SIZE2,SIZE1andSIZE0signals(outputsignals)
These 4 signals are outputted in the combination of 4 sizes for the paper to be copied.
Theyarethesignalsforthecoincontroller,andareoutputtedfromtheLGCboard.
7.LARGE/SMALLsignal(outputsignal)
Whenlargesizepaper(A3/A3wide/LD)isselectedorpapersizeisnotspeciedwiththe
manual feeding, it outputs“Low” in real time. In other cases, it outputs “High”.The setting
changeforlargesizepaperisperformedwithF/W.
This is the signal only for the coin controller.
8.FULLCOLORsignal(outputsignal)
Ifthefullcolormodeisselected,itoutputs“Low”inrealtime.Inothercases,itoutputs“High”.
Bydefault,itoutputs“Low”sinceitissetasfullcolormode.
This is the signal only for the coin controller.
9.TWN/MONCOLORsignal(outputsignal)
Ifthetwincolorormonocolormodeisselected,itoutputs“Low”inrealtime.Inothercases,
itoutputs“High”.Thisisthesignalonlyforthecoincontroller.
10.B/Wsignal(outputsignal)
Iftheblackmodeisselected,itoutputs“Low”inrealtime.Inothercases,itoutputs“High”.
This is the signal only for the coin controller.
11.KCTRONsignal(outputsignal)
Thesesignalsaresynchronizedwiththeelectroniccounteroftheequipmentandthey
become“Low”whenthecounteristurnedON.Theyarethesignalsfordrivingamechanical
counter,andoutputfromtheLGCboard.
Theycandriveinductiveloads,suchasasolenoid,using24Vsuppliedfromtheequipment.
The interval between when they are turned ON and when this happens next must be at least
100 ms.“Single count”or “Double count” can be switched according to the paper size by
setting“1”or“2”for08-6010.