45584901TH Rev.1
11-128 /
Oki Data CONFIDENTIAL
05/08 Mode Element
Sub
element
Item Subitem Code
Sub-
code
Details
Default
value
Acceptable
value
RAM Contents
Proce-
dure
08 Setting
mode
System General 9012 Languageselection
to be displayed at
power-ON
English
- SYS en_US:Englishde_DE:Germanfr_FR:French
es_ES:Spanishit_IT:Italianja_JP:Japanese
en_GB:English(British)zh_CN:SimpliedChinese
zh_TW:TraditionalChineseko_KR:Korean
<Default value>
ODA: English
Others: English (British)
11
08 Setting
mode
System User
interface
9016 Externally installed
counter
0 0-3,5 SYS 0: No external counter
1:Coincontroller(Ifthevalueof08-9979is"0"(ACS),it
is changed to "2" (Full color).)
2: Copy key card (This value is valid only when "2" is set
for 08-9000.)
3:Keycopycounter
5: Coin controller supporting ACS/mixed-size (The value
of 08-4131 is set to "1")
* This code is a special code which has areas in both
SYS-SRAMandPU.ThedefaultvalueinSYS-SRAMis
applied to the PU area at initialization.
1
08 Setting
mode
System Counter 9017 Setting for counter
installed externally
1 0,1,4,5 SYS Selects the job to count up for the external counter.
0: Not selected
1: Copier
4: Printer
5: Copier/Printer
* This code is a special code which has areas in both
SYS-SRAMandPU.ThedefaultvalueinSYS-SRAMis
applied to the PU area at initialization.
1
08 Setting
Mode
System General Memory 9020 Size information of
memory
- - SYS Displays the sizes of the main memory and page
memory.
Enables to check if each memory is properly
2
08 Setting
Mode
System Initializa-
tion
9030 Initialization after
software version up
- - SYS Performthiscodewhenthesoftwareinthisequipment
has been upgraded.
3
08 Setting
Mode
System User
interface
Counter installed
externally
9037 Job handling-short
paid-coin controller
1 0-1 SYS Sets whether pause or stop the printing job when it is
short paid using a coin controller.
0: Pause the job
1: Stop the job
1
08 Setting
Mode
System Mainte-
nance
General 9050 Performing panel
calibration
- - SYS Performs the calibration of the pressing position on the
touchpanel(LCDscreen).
The calibration is performed by pressing 4 reference
positions after this code is started up.
1
08 Setting
Mode
System User
interface
Display setting 9051 Panel calibration
setting value
0 0-1 SYS Switches whether the screen for displaying panel
calibration setting values is displayed or not.
0: Disabled (screen not displayed)
1: Enabled (screen displayed)
1