45584901TH Rev.1
11-139 /
Oki Data CONFIDENTIAL
05/08 Mode Element
Sub
element
Item Subitem Code
Sub-
code
Details
Default
value
Acceptable
value
RAM Contents
Proce-
dure
08 Setting
mode
System Image Binarizing level
setting
(Whenjudgingas
black in the ACS
Mode)
9230 2 Step 0 (center) 175 0-255 SYS Sets the binarizing level of each step.
Whenthevalueincreases,theimagebecomesdarker.
Whenthevaluedecreases,theimagebecomeslighter.
Refer to 08-9204.
4
08 Setting
mode
System Image Binarizing level
setting
(Whenjudgingas
black in the ACS
Mode)
9230 3 Step +1 205 0-255 SYS Sets the binarizing level of each step.
Whenthevalueincreases,theimagebecomesdarker.
Whenthevaluedecreases,theimagebecomeslighter.
Refer to 08-9204.
4
08 Setting
mode
System Image Binarizing level
setting
(Whenjudgingas
black in the ACS
Mode)
9230 4 Step +2 235 0-255 SYS Sets the binarizing level of each step.
Whenthevalueincreases,theimagebecomesdarker.
Whenthevaluedecreases,theimagebecomeslighter.
Refer to 08-9204.
4
08 Setting
mode
System Scanning 9233 Equipmentname
and user name
setting to a folder
when saving files
0 0-2 SYS Setswhetherornotaddingtheequipmentnameand
user name to the folder when saving files.0: Not add
1:Addtheequipmentname
2: Add the user name
1
08 Setting
mode
System User
interface
Default screen setting 9236 Default setting of
print screen
1 1-4 SYS 1: Private print screen (Job list of log-in user is displayed
if user authentication is enabled.)
2: Hold print screen (Job list of log-in user is displayed if
user authentication is enabled.)
3: Private print screen (If the private print screen is
displayedwhenuserauthenticationisenabled,user
listisdisplayedifuserlogsinasGUEST,andjoblistof
log-in user is displayed if user logs in as general user.)
4: Hold print screen (If the private print screen is
displayedwhenuserauthenticationisenabled,user
listisdisplayedifuserlogsinasGUEST,andjoblistof
log-in user is displayed if user logs in as general user.)
* If user data department management (08-9264) is
changedfromOFFtoON,thevalueinthiscodechanges
from"1"to"2",and"3"to"4".Thevaluedoesnotchange
if it is "2" or"4". Reset this value as necessary when
changing user data department management (08-9264)
from OFF to ON.
1