45584901TH Rev.1
11-146 /
Oki Data CONFIDENTIAL
05/08 Mode Element
Sub
element
Item Subitem Code
Sub-
code
Details
Default
value
Acceptable
value
RAM Contents
Proce-
dure
08 Setting
mode
System Paper
feeding
Paper size (MPT/non-
standard type)
9318 Memory 1 127/64 127-356/
64-216
SYS Registers the paper size of MPT (non-standard type) into
[MEMORY1].
Feeding/Widthwisedirection.
10
08 Setting
mode
System Paper
feeding
Paper size (MPT/non-
standard type)
9319 Memory 2 127/64 127-356/
64-216
SYS Registers the paper size of MPT (non-standard type) into
[MEMORY2].
Feeding/Widthwisedirection.
10
08 Setting
mode
System Paper
feeding
Paper size (MPT/non-
standard type)
9320 Memory 3 127/64 127-356/
64-216
SYS Registers the paper size of MPT (non-standard type) into
[MEMORY3].
Feeding/Widthwisedirection.
10
08 Setting
mode
System Paper
feeding
Paper size (MPT/non-
standard type)
9321 Memory 4 127/64 127-356/
64-216
SYS Registers the paper size of MPT (non-standard type) into
[MEMORY4].
Feeding/Widthwisedirection.
10
08 Setting
Mode
System User
interface
Sound 9325 Keytouchsoundof
control panel
1 0-1 SYS 0: OFF
1: ON
1
08 Setting
mode
System General Banner advertising 9327 Setting of banner
advertising display
0 0-1 SYS Sets whether or not displaying the banner advertising.
The setting contents of 08-9328 and 9329 are displayed
at the time display section on the right top of the screen.
Whenbothareset,eachcontentisdisplayedalternately.
0: Not displayed
1: Displayed
1
08 Setting
mode
System General Banner advertising 9328 Banner advertising
display 1
- - SYS Maximum 27 letters (one-byte character) 11
08 Setting
mode
System General Banner advertising 9329 Banner advertising
display 2
- - SYS Maximum 27 letters (one-byte character) 11
08 Setting
mode
System General Banner advertising 9330 Display of [BANNER
MESSAGE] button
0 0-1 SYS 0: Not displayed
1: Displayed
This button enables the entry of "Banner advertising
display 1 (08-9328)" and "Banner advertising display 2
(08-9329)" on the control panel.
1
08 Setting
mode
System Network 9331 LocalI/Ftime-out
period
6 1-50 SYS Sets the period of time when the job is judged as
completed in local I/F printing (USB or parallel).
1: 1.0 sec.
2: 1.5 sec.
50: 25.5 sec.
(in increments of 0.5 sec.)
1
08 Setting
mode
System User
interface
9332 Original counter
display
Refer
to
contents
0-4 SYS Sets whether the original counter is displayed or not.
0: Not displayed
2: Displayed
4: Displayed (Double sized original is counted as 2.)
<Default value>
ODA: 0
Others: 2
1