45584901TH Rev.1
11-169 /
Oki Data CONFIDENTIAL
05/08 Mode Element
Sub
element
Item Subitem Code
Sub-
code
Details
Default
value
Acceptable
value
RAM Contents
Proce-
dure
08 Setting
mode
System Network DHCP 9580 Enabling server's IP
addressacquiredby
DHCP
1 1-2 - Domain Name Server option (6)
1: Enabled
2: Disabled
This value is used only when DHCP is enabled.
12
08 Setting
mode
System Network DHCP 9581 Enabling server's IP
addressacquiredby
DHCP
1 1-2 - NetBIOSoverTCP/IPNameServeroption(44)=
PrimaryandSecondaryWinsNAME
1: Enabled
2: Disabled
This value is used only when DHCP is enabled.
12
08 Setting
mode
System Network SMTP 9584 SMTP Server
Option (69) Simple
Mail Server Address
2 1-2 - OFF/ON
1:Valid
2: Invalid
12
08 Setting
mode
System Network POP3 9585 POP3 Server Option
(70) Post Office
Server Address
2 1-2 - OFF/ON
1:Valid
2: Invalid
12
08 Setting
mode
System Network DHCP 9587 Enabling server's IP
addressacquiredby
DHCP
2 1-2 - SNTP Server Option (42) NTP Server Address
1: Enabled
2: Disabled
This value is used only when DHCP is enabled.
12
08 Setting
mode
System Network SMB 9599 Samba server
ON/OFF setting
1 1-4 NIC 1: Samba enabled
2: Samba disabled
3: Print Share disabled
4: File Share disabled
12
08 Setting
Mode
System Mainte-
nance
General 9601 Equipmentnumber
(serial number)
display
- 9 digits SYS Fist digit: Production country (fixed)
Second digit: Model (fixed)
Third digit: Month (variable)
Fourth to ninth digit: serial number (variable)
This can be also entered with 05-9043.
11
08 Setting
mode
System Mainte-
nance
9602 Dealer's name - - SYS Maximum 100 letters Needed at initial registration 11
08 Setting
Mode
System Mainte-
nance
RDMS 9603 Loginname - 20 letters SYS Maximum 20 letters
Needed at initial registration
11
08 Setting
Mode
System Mainte-
nance
Remote-controlled
service
Call /Display
function
9604 Display set of
Service
Notification button
1 0-1 SYS 0: Not displayed
1: Displayed
1
08 Setting
mode
System Mainte-
nance
RDMS 9605 Sending error
contents of
equipment
0 0-1 SYS 0: Invalid
1:Valid
1
08 Setting
mode
System Mainte-
nance
Remote-controlled
service
9606 Setting total counter
transmission
interval
- - SYS (Hour/Hour/Minute/Minute) 1
08 Setting
mode
System Mainte-
nance
Remote-controlled
service
9607 Destination E-mail
address 2
- - SYS Maximum 192 letters 11