Loading...
45584901TH Rev.1
11-177 /
Oki Data CONFIDENTIAL
05/08 Mode Element
Sub
element
Item Subitem Code
Sub-
code
Details
Default
value
Acceptable
value
RAM Contents
Proce-
dure
08 Setting
mode
System General 9816 Addition of the page
number to the multi-
page file name of
File
0 0-1 SYS Only when job is executed with TimeStamp enabled for
lestorage,pagenumberisaddedwiththeformatsetat
08-9387.
0: Invalid (Page number not added)
1:Valid(Pagenumberadded)
1
08 Setting
mode
System General 9817 Maximum number
of decimals in the
extension fields
2 0-6 SYS 0 to 6 digits 1
08 Setting
mode
System General 9818 The default value of
the stored/attached
file name of a File/
Email
0 0-1 SYS 0:DOCYYMMDD
1: NetBios name
1
08 Setting
mode
System User
interface
Off Device
Customization
Architecture
9819 STAGESSL 0 0-1 SYS SetswhetherSSLcommunicationisenabledordisabled
for remote scanning.
0: Disabled
1: Enabled
1
08 Setting
mode
System User
interface
Off Device
Customization
Architecture
9820 STAGE I/F 1 0-1 SYS Sets whether interface is enabled or disabled for remote
scanning.
0: Disabled
1: Enabled
1
08 Setting
mode
System User
interface
Off Device
Customization
Architecture
9821 Port number 49629 0-65535 SYS Sets a port number for the remote scanning. 1
08 Setting
mode
System User
interface
Off Device
Customization
Architecture
9822 SSLportnumber 49630 0-65535 SYS SetsanSSLportnumberforremotescanningusing
SSLcommunication.
1
08 Setting
mode
System Network 9823 User name and
password at user
authentication or
"Save as file"
0 0-2 SYS 0: User name and password of the device
1: User name and password at the user authentication
(Template registration information comes first when a
template is retrieved.)
2: User name and password at the user authentication
(User information of the authentication comes first when
a template is retrieved.)
1
08 Setting
mode
System Image 9825 Imagequalityofthe
black part in the
ACS mode
0 0-1 SYS 0: Black
1: Gray scale
1
08 Setting
mode
System General Department
management
9829 Limitationsetting 0 0-3 SYS Decide the default limitation setting when the new
department code is created.
0: No limit
1:Limitedonlyintheblackmode
2:Limitedinthecolormode
3:Limitedintheblack/colormode
1