251
Pulse Outputs Section 5-2
Input interrupt task 0 (interrupt task number 140) starts a scheduled interrupt
with a scheduled time of 0.5 ms. The scheduled interrupt task executes the
pulse output instructions and stops the scheduled interrupt.
Instructions Used MSKS(690) Enables the I/O interrupt. Starts the scheduled interrupt.
PULS(886) Sets the number of output pulses.
SPED(885) Starts the pulse output.
Preparation
PLC Setup
Built-in Input Settings
Pulse Output 0 Settings
MSKS
PULS SPED
Pulse output 0
(CIO 100.00)
Interrupt input 0
(CIO 0.04)
I/O interrupt
response time
Scheduled interrupt
time 500 µs
PLC Setup setting details
Use built-in input 0.04 as the interrupt input.
PLC Setup setting details
Do not use high-speed counter 0.
Do not use the pulse output 0 origin search function.