176
High-speed Counters Section 5-1
5-1 High-speed Counters
5-1-1 Overview
A rotary encoder can be connected to a built-in input to produce a high-
speed pulse input.
The PRV(881) instruction can be used to measure the input pulse fre-
quency (one input only).
The high-speed counter PVs can be maintained or refreshed.
The High-speed Counter Gate Bit can be turned ON/OFF from the ladder
program to select whether the high-speed counter PVs will be maintained
or refreshed.
Any one of the following input signals can be selected as the counter input
mode.
Response Frequencies for 24 VDC Inputs to High-speed Counters 0 and 1:
Differential phase inputs (4x): 50 kHz
Pulse + direction inputs: 100 kHz
Up/Down pulse inputs: 100 kHz
Increment pulse inputs: 100 kHz
Response Frequencies of CP1L-J show below:
Differential phase inputs (4x): 10 kHz
Pulse + direction inputs: 20 kHz
Up/Down pulse inputs: 20 kHz
Increment pulse inputs: 20 kHz
The counting mode can be set to linear mode or circular (ring) mode.
The counter reset method can be set to Z phase signal + software reset,
software reset, Z phase signal + software reset (continue comparing), or
software reset (continue comparing).
Pulse Input Functions
Purpose Function used Description
Receive incremental rotary
encoder inputs to calculate
length or position.
High-speed counter
function
Built-in input terminals can be used for high-speed counter
inputs.
The PV for the high-speed counters are stored in the Auxiliary
Area.
The counters can be operated in ring mode or linear mode.
Measure a workpiece's length
or position.
(Start counting when a certain
condition is established or
pause counting when a certain
condition is established.)
High-speed Counter
Gate Bit
The high-speed counter can be started or stopped (PV held)
from the Unit's program by turning ON/OFF the High-speed
Counter Gate Bit when the desired condition is met.
Measure a workpiece's speed
from its position data (frequency
measurement.)
PRV(881) HIGH-
SPEED COUNTER
PV READ
The PRV(881) instruction can be used to measure the pulse fre-
quency.
Range with differential phase inputs: 0 to 50 kHz (Y models: 0
to 500 kHz, J models : 0 to 10kHz)
Range with all other input modes: 0 to 100 kHz (Y models: 0 to
1 MHz, J models : 0 to 20kHz))
PRV2(883) PULSE
FREQUENCY CON-
VERT
PRV2(883) reads the pulse frequency and converts it to a rota-
tional speed (r/min) or it converts the counter PV to a total num-
ber of rotations. Results are calculated by the number of pulses/
rotation.