713
PLC Setup Appendix G
Pulse Output 1 Settings
Base Settings
Name Default Settings When setting is read
by CPU Unit
Internal
address
Bits Settings
1 Undefined Origin (oper-
ation for limit signal turn-
ing ON)
Hold Hold At start of operation 286 12 to
15
0 hex
Undefined 1 hex
2 Limited Input Signal
Operation
Search Only Search Only When power is turned
ON
274 04 to
07
0 hex
Always 1 hex
3 Limit Input Signal NC NC At start of operation 286 00 to
03
0 hex
NO 1 hex
4 Search/Return Initial
Speed
0 pps
(disabled)
0 pps At start of operation 277 and
276
00 to
15
0000 0001
hex
: :
100,000 pps 0001 86A0
hex
000F 4240
hex
5 Speed Curve Trapezium Trapezium When power is turned
ON
274 12 to
15
0 hex
S-shaped 1 hex

Table of Contents