256
Pulse Outputs Section 5-2
Ladder Program
Target frequency (high speed): 100,000 Hz D011 86A0
D12 0001
Deceleration rate: 100 Hz/4 ms (Not used.) D13 0064
Target frequency (stop): 0 Hz D14 0000
D15 0000
Setting details Address Data
#0001
#0001
#0000
#0001
#0001
#0000
0.00 A281.04
W0.00 0.00
0.01 A281.04
W0.01 0.01
SPED(885)
SPED(885)
SPED(885)
#0000
D0
SET W0.00
#0000
RSET W0.00
#0010
D0
SET W0.01
SPED(885)
#0010
RSET W0.01
Low-speed
CW Start
Pulse Output
in Progress
Pulse output 1
Specifies CW/CCW output method,
CW side, and continuous mode.
Target frequency
Low-speed
CW output in
progress
Low-speed
CW Start
Low-speed
CCW Start
Outputting
Pulses
Pulse output 1
Specifies CW/CCW output method,
CW side, and continuous mode.
Target frequency
Low-speed
CCW output
in progress
Low-speed
CCW Start