259
Pulse Outputs Section 5-2
Settings for PLS2(887) for Fixed-distance Feeding (D10 to D20)
Ladder Program
Setting details Address Data
Acceleration rate: 1,000 Hz/4 ms D10 03E8
Deceleration rate: 1,000 Hz/4 ms D11 03E8
Target frequency: 10,000 Hz D12 2710
D13 0000
Number of output pulses: 50,000 pulses D14 C350
D15 0000
Starting frequency: 0000 Hz D16 0000
D17 0000
Counter setting: 100 times D20 0100
SPED(885)
#0000
#0000
D0
0.00
SET W0.00
A280.04
SPED(885)
#0000
#0000
D2
0.00
RSET W0.00
W0.00
@PLS2(887)
#0000
#0000
D10
D16
0.01
0.02
CNT
0000
D20
A280.03
100.02
A280.03
0.01
C0000
100.03
INI(880)
#0000
#0003
0
0.03
Jog Operation
Jogging
Switch
Pulse Output
In-Progress
Flag
Target frequency:
1,000 Hz
Jogging Flag
Jogging
Switch
Jogging
Flag
Target frequency:
0Hz
Jogging Flag
Fixed-distance Feed
Positioning
Switch
Cutter
Finished
Pulse Output
Completed Flag
Cutter activated
Counting Feed Operations
Emergency
Stop
Cutting Operation
Finished
Pulse Output
Completed Flag
Positioning
Switch