270
Pulse Outputs Section 5-2
■ DM Area Settings
Starting Frequency
PLS2(887) Settings to Move from Origin to Position A
PLS2(887) Settings to Move from Position A to Position B
Setting details Address Data
X-axis starting frequency D0 0000
Y-axis starting frequency D2 0000
Setting details Address Data
X axis Acceleration rate: 2,000 Hz/4 ms D10 07D0
Deceleration rate: 2,000 Hz/4 ms D11 07D0
Target frequency: 100,000 Hz D12 86A0
D13 0001
Number of output pulses: 5,000 pulses D14 1388
D15 0000
Y axis Acceleration rate: 2,000 Hz/4 ms D20 07D0
Deceleration rate: 2,000 Hz/4 ms D21 07D0
Target frequency: 100,000 Hz D22 86A0
D23 0001
Number of output pulses: 5,000 pulses D24 1388
D25 0000
Setting details Address Data
X axis Acceleration rate: 2,000 Hz/4 ms D30 07D0
Deceleration rate: 2,000 Hz/4 ms D31 07D0
Target frequency: 100,000 Hz D32 86A0
D33 0001
Number of output pulses: 25,000 pulses D34 61A8
D35 0000