655
Auxiliary Area Allocations by Address Appendix D
A540 A540.10 Pulse Out-
put 0 Posi-
tioning
Completed
Signal
This is the positioning completed
input signal used in the origin search
for pulse output 0. The input signal
from the servo driver is output to this
bit from the ladder program to enable
using the signal.
--- Retained Cleared ---
A541 A541.00 Pulse Out-
put 1 Reset
Bit
The pulse output 1 PV (contained in
A278 and A279) will be cleared when
this bit is turned ON.
--- Retained Cleared --- A278 and
A279
A541.08 Pulse Out-
put 1 CW
Limit Input
Signal Flag
This is the CW limit input signal for
pulse output 1, which is used in the
origin search. To use this signal,
write the input from the actual sensor
as an input condition in the ladder
program and output the result to this
flag.
--- Retained Cleared --- ---
A541.09 Pulse Out-
put 1 CCW
Limit Input
Signal Flag
This is the CCW limit input signal for
pulse output 1, which is used in the
origin search. To use this signal,
write the input from the actual sensor
as an input condition in the ladder
program and output the result to this
flag.
--- Retained Cleared --- ---
A541.10 Pulse Out-
put 1 Posi-
tioning
Completed
Signal
This is the positioning completed
input signal used in the origin search
for pulse output 1. The input signal
from the servo driver is output to this
bit from the ladder program to enable
using the signal.
--- Retained Cleared --- ---
A562 A562.00 Error
Counter 0
Reset Bit
Turn ON this bit to reset the Error
Counter 0 Present Value and turn
OFF the Error Counter 0 Error Flag.
--- --- Cleared --- ---
A562.01 Error
Counter 0
Disable Bit
Turn ON this bit to hold the present
value of error counter 0.
ON: Error
counter value
held.
OFF: Error
counter value
not held.
--- Cleared --- ---
A563 A563.00 Error
Counter 1
Reset Bit
Turn ON this bit to reset the Error
Counter 1 Present Value and turn
OFF the Error Counter 0 Error Flag.
--- --- Cleared --- ---
A563.01 Error
Counter 1
Disable Bit
Turn ON this bit to hold the present
value of error counter 1.
ON: Error
counter value
held.
OFF: Error
counter value
not held.
--- Cleared --- ---
A580 A580.00
to
A580.03
FB Commu-
nications
Instruction
Retries
Automatically stores the number of
retries in the FB communications
instruction settings specified in the
PLC Setup.
0 to F hex --- Cleared Written at
start of
operation
A581 All FB Commu-
nications
Instruction
Response
Monitoring
Time
Automatically stores the FB commu-
nications instruction response moni-
toring time set in the PLC Setup.
0001 to FFFF
hex (Unit: 0.1 s;
Range: 0.1 to
6553.5)
0000 hex: 2 s
--- Cleared Written at
start of
operation
---
Addresses Name Function Settings Status
after
mode
change
Status at
startup
Write
timing
Related
Flags,
Settings
Word Bits

Table of Contents