EasyManuals Logo

Omron F3SJ Series User Manual

Omron F3SJ Series
224 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #113 background imageLoading...
Page #113 background image
93
F3SJ-A
User’s Manual
Chapter3 Setting Adjusted to Application
What can be done by the setting tool
E
2. Zone Overlap Condition
A condition to configure setting zones as overlapped.
Except for combination of muting zone and fixed blanking zone (figure 3), setting zones of these 4
functions cannot be configured as overlapped. (Figure 4)
Zone overlap condition
: Setup available
x: Setting not possible
Even if a muting zone and a fixed blanking zone are configured as overlapped, fixed blanking monitoring function is
effective. Thus a fixed blanking beam receives light under muting, operation is based on setting of the monitoring
function.
Muting Function
Fixed Blanking
Function
Floating Blanking
Function
Warning Zone
Function
Muting Function - xx
Fixed Blanking Function xxx
Floating Blanking Function x x - x
Warning Zone Function x x x -
Muting zone
Fixed blanking zone
Floating blanking zone
Fixed blanking zone
Muting zone
Alarm zone
Figure 4Figure 3

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Omron F3SJ Series and is the answer not in the manual?

Omron F3SJ Series Specifications

General IconGeneral
TypeSafety Light Curtain
Safety CategoryCategory 4
Protection RatingIP67
SILSIL3
Operating Temperature-10°C to +55°C
Detection MethodInfrared
Resolution14 mm
IP RatingIP67
CertificationCE
Power Supply Voltage24 VDC ±10%

Related product manuals