4 Parameter List
4 - 37
Multi-function Compact Inverter 3G3MX2-EV2 User’s Manual (I666-E1)
Parameter
No.
Function name
Monitor or data range
Default
data
Set
data
Changes
during
RUN
Unit
Page
Simple
position
control
P075
Position Control
Mode Selection
00: Limit
01: No limit
00
Disabled
P. 6-34
P077
Encoder Disconnec-
tion Detection Time
0.0:
Disconnection detection disabled
0.1 to 10.0
1.0
Enabled
s
P080
Restarting Positioning
Range Setting
0. to 10000. (×4 multiplication)
0.
Disabled
pulse
P. 6-45
P081
Position Store Selec-
tion at Power Off
00: Not store
01: Store
00
Enabled
P. 6-44
P082
Position Data at
Power Off
Position Limit Setting (Reverse Side)
(P073) to Position Limit Setting (Forward
Side)
*1
(Displays upper 5 digits excluding -”)
(×1 multiplication)
0
Enabled
pulse
P. 6-44
P083
Preset Position Data
Position Limit Setting (Reverse Side)
(P073) to Position Limit Setting (Forward
Side)
*1
(Displays upper 5 digits excluding -”)
(×1 multiplication)
0
Enabled
pulse
P. 6-43
DriveProgramming
P100
DriveProgramming
User Parameter U00
to U31
0. to 65535.
0.
Enabled
P.
7-105
P101
P102
P103
P104
P105
P106
P107
P108
P109
P110
P111
P112
P113
P114
P115
P116
P117
P118
P119
P120
P121
P122
P123
P124
P125
P126
P127
P128
P129
P130
P131
4
4-3 Extended Function Mode
4-3-5 Group P: Option/Applied Function Parameters

Table of Contents