4 Parameter List
4 - 38
Multi-function Compact Inverter 3G3MX2-EV2 User’s Manual (I666-E1)
Parameter
No.
Function name
Monitor or data range
Default
data
Set
data
Changes
during
RUN
Unit
Page
Co-inverter
communication
P140
Number of Sent Data of
All Stations in Co-
inverter Communication
1. to 5.
5.
Enabled
P. 8-31
P141
Recipient Station Num-
ber of All Stations in Co-
inverter Communica-
tion 1
1. to 247.
1.
Enabled
P142
Recipient Register of All
Stations in Co-inverter
Communication 1
0000 to FFFF hex
0000
Enabled
P143
Sender Register of All
Stations in Co-inverter
Communication 1
0000 to FFFF hex
0000
Enabled
P144
Recipient Station Num-
ber of All Stations in Co-
inverter Communica-
tion 2
1. to 247.
2.
Enabled
P145
Recipient Register of All
Stations in Co-inverter
Communication 2
0000 to FFFF hex
0000
Enabled
P146
Sender Register of All
Stations in Co-inverter
Communication 2
0000 to FFFF hex
0000
Enabled
P147
Recipient Station Num-
ber of All Stations in Co-
inverter Communica-
tion 3
1. to 247.
3.
Enabled
P148
Recipient Register of All
Stations in Co-inverter
Communication 3
0000 to FFFF hex
0000
Enabled
P149
Sender Register of All
Stations in Co-inverter
Communication 3
0000 to FFFF hex
0000
Enabled
P150
Recipient Station Num-
ber of All Stations in Co-
inverter Communica-
tion 4
1. to 247.
4.
Enabled
P151
Recipient Register of All
Stations in Co-inverter
Communication 4
0000 to FFFF hex
0000
Enabled
P152
Sender Register of All
Stations in Co-inverter
Communication 4
0000 to FFFF hex
0000
Enabled
P153
Recipient Station Num-
ber of All Stations in Co-
inverter Communica-
tion 5
1. to 247.
5.
Enabled
P154
Recipient Register of All
Stations in Co-inverter
Communication 5
0000 to FFFF hex
0000
Enabled
P155
Sender Register of All
Stations in Co-inverter
Communication 5
0000 to FFFF hex
0000
Enabled

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Omron MX2 Series and is the answer not in the manual?

Omron MX2 Series Specifications

General IconGeneral
Cooling MethodFan cooling
Output Frequency Range0.1 to 400 Hz
Control MethodV/f control, Sensorless vector control
Protection FunctionsOvercurrent, overvoltage, undervoltage, overload, overheating, short circuit
Communication OptionsModbus RTU
Overload Capacity150% for 60 seconds
Braking UnitBuilt-in
Ambient Operating Temperature-10°C to +50°C
EnclosureIP20
Storage Temperature-20°C to +65°C
Humidity5 to 95% RH (non-condensing)
AltitudeUp to 1000m
Power Supply Voltage200-240V AC
Input Voltage3-phase 200-240V AC