EasyManuals Logo

Omron MX2 Series User Manual

Omron MX2 Series
612 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #529 background imageLoading...
Page #529 background image
8 Communications Functions
8 - 85
Multi-function Compact Inverter 3G3MX2-EV2 User’s Manual (I666-E1)
Register
No.
Modbus
register
spec. No
Function name
Parameter
No.
R/W
Monitor or setting data
Data
resolution
Page
1610
hex
Reserved
1611
hex
1610 hex
Positioning
Completion Range
Setting
P017
R/W
0 to 10000
1
[pulse]
P. 6-34
1612
to
1619
hex
Reserved
161A
hex
1619 hex
Overspeed Error
Detection Level
P026
R/W
0 to 1500
0.1 [%]
P. 6-23
161B
hex
161A hex
Speed Deviation
Excessive Level
P027
R/W
0 to 12000
0.01
[Hz]
161C to
161E
hex
Reserved
161F
hex
161E hex
Acceleration/
Deceleration Time
Input Type
P031
R/W
00: Digital Operator
03: DriveProgramming
P. 5-32
1620
hex
Reserved
1621
hex
1620 hex
Torque Reference
Input Selection
P033
R/W
00: Terminal O
01: Terminal OI
03: Digital Operator
06: Option (No applica-
ble Option)
P. 6-16
1622
hex
1621 hex
Torque Reference
Setting
P034
R/W
0 to 200
1 [%]
1623
hex
Reserved
1624
hex
1623 hex
Torque Bias Selec-
tion
P036
R/W
00: Disabled
01: Digital Operator
05: Option (No applica-
ble Option)
P. 6-17
1625
hex
1624 hex
Torque Bias Value
P037
R/W
200 to 200
1 [%]
1626
hex
1625 hex
Torque Bias Polarity
Selection
P038
R/W
00: As per sign
01: Dependent on
RUN direction
1627
hex
Reserved
1628
hex
1627 hex
Speed Limit Value in
Torque Control
(Forward)
P039
R/W
0 to 12000
0.01
[Hz]
P. 6-16
1629
hex
Reserved
162A
hex
1629 hex
Speed Limit Value in
Torque Control
(Reverse)
P040
R/W
0 to 12000
0.01
[Hz]
P. 6-16
162B
hex
162A hex
Speed/Torque
Switching Time
P041
R/W
0 to 1000
1 [ms]
162C to
1638
hex
Reserved
8
8-9 Modbus Communication Data Lists
8-9-4 Group A/b/C/H/P Register List

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Omron MX2 Series and is the answer not in the manual?

Omron MX2 Series Specifications

General IconGeneral
Cooling MethodFan cooling
Output Frequency Range0.1 to 400 Hz
Control MethodV/f control, Sensorless vector control
Protection FunctionsOvercurrent, overvoltage, undervoltage, overload, overheating, short circuit
Communication OptionsModbus RTU
Overload Capacity150% for 60 seconds
Braking UnitBuilt-in
Ambient Operating Temperature-10°C to +50°C
EnclosureIP20
Storage Temperature-20°C to +65°C
Humidity5 to 95% RH (non-condensing)
AltitudeUp to 1000m
Power Supply Voltage200-240V AC
Input Voltage3-phase 200-240V AC

Related product manuals