EasyManuals Logo

Omron MX2 Series User Manual

Omron MX2 Series
612 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #535 background imageLoading...
Page #535 background image
8 Communications Functions
8 - 91
Multi-function Compact Inverter 3G3MX2-EV2 User’s Manual (I666-E1)
Register
No.
Modbus
register
spec. No
Function name
Parameter
No.
R/W
Monitor or setting data
Data
resolution
Page
16A5
hex
16A4 hex
Option I/F Flexible
Format Output
Register 4
P163
R/W
0000 to FFFF hex
1
P. 7-105
16A6
hex
16A5 hex
Option I/F Flexible
Format Output
Register 5
P164
R/W
0000 to FFFF hex
1
16A7
hex
16A6 hex
Option I/F Flexible
Format Output
Register 6
P165
R/W
0000 to FFFF hex
1
16A8
hex
16A7 hex
Option I/F Flexible
Format Output
Register 7
P166
R/W
0000 to FFFF hex
1
16A9
hex
16A8 hex
Option I/F Flexible
Format Output
Register 8
P167
R/W
0000 to FFFF hex
1
16AA
hex
16A9 hex
Option I/F Flexible
Format Output
Register 9
P168
R/W
0000 to FFFF hex
1
16AB
hex
16AA hex
Option I/F Flexible
Format Output
Register 10
P169
R/W
0000 to FFFF hex
1
16AC
hex
16AB hex
Option I/F Flexible
Format Input
Register 1
P170
R/W
0000 to FFFF hex
1
16AD
hex
16AC hex
Option I/F Flexible
Format Input
Register 2
P171
R/W
0000 to FFFF hex
1
16AE
hex
16AD hex
Option I/F Flexible
Format Input
Register 3
P172
R/W
0000 to FFFF hex
1
16AF
hex
16AE hex
Option I/F Flexible
Format Input
Register 4
P173
R/W
0000 to FFFF hex
1
16B0
hex
16AF hex
Option I/F Flexible
Format Input
Register 5
P174
R/W
0000 to FFFF hex
1
16B1
hex
16B0 hex
Option I/F Flexible
Format Input
Register 6
P175
R/W
0000 to FFFF hex
1
16B2
hex
16B1 hex
Option I/F Flexible
Format Input
Register 7
P176
R/W
0000 to FFFF hex
1
16B3
hex
16B2 hex
Option I/F Flexible
Format Input
Register 8
P177
R/W
0000 to FFFF hex
1
16B4
hex
16B3 hex
Option I/F Flexible
Format Input
Register 9
P178
R/W
0000 to FFFF hex
1
16B5
hex
16B4 hex
Option I/F Flexible
Format Input
Register 10
P179
R/W
0000 to FFFF hex
1
16B6
hex
16B5 hex
(Reserved)
P180
Do not change the
default 0.
8
8-9 Modbus Communication Data Lists
8-9-4 Group A/b/C/H/P Register List

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Omron MX2 Series and is the answer not in the manual?

Omron MX2 Series Specifications

General IconGeneral
Cooling MethodFan cooling
Output Frequency Range0.1 to 400 Hz
Control MethodV/f control, Sensorless vector control
Protection FunctionsOvercurrent, overvoltage, undervoltage, overload, overheating, short circuit
Communication OptionsModbus RTU
Overload Capacity150% for 60 seconds
Braking UnitBuilt-in
Ambient Operating Temperature-10°C to +50°C
EnclosureIP20
Storage Temperature-20°C to +65°C
Humidity5 to 95% RH (non-condensing)
AltitudeUp to 1000m
Power Supply Voltage200-240V AC
Input Voltage3-phase 200-240V AC

Related product manuals