8 Communications Functions
8 - 92
Multi-function Compact Inverter 3G3MX2-EV2 User’s Manual (I666-E1)
Register
No.
Modbus
register
spec. No
Function name
Parameter
No.
R/W
Monitor or setting data
Data
resolution
Page
16B7
hex
16B6 hex
(Reserved)
P181
Do not change the
default 0.
16B8
hex
16B7 hex
(Reserved)
P182
Do not change the
default 0.
16B9
hex
16B8 hex
(Reserved)
P183
Do not change the
default 0.
16BA
hex
Reserved
16BB
hex
16BA hex
(Reserved)
P185
Do not change the
default 0.
16BC
hex
16BB hex
(Reserved)
P186
Do not change the
default 6.
16BD to
16BF
hex
Not used
Not accessible
16C0
hex
16BF hex
(Reserved)
P190
Do not change the
default 0.
16C1
hex
Not used
Not accessible
16C2
hex
16C1 hex
(Reserved)
P192
Do not change the
default 63.
16C3
hex
Not used
Not accessible
16C4
hex
16C5
hex
16C4 hex
(Reserved)
P195
Do not change the
default 0.
16C6
hex
16C5 hex
(Reserved)
P196
Do not change the
default 21.
16C7
hex
Not used
Not accessible
16C8
hex
16C7 hex
Modbus Mapping
Function Selection
P200
R/W
00: Standard Modbus
address
01: Modbus mapping
enabled
P. 8-24
16C9
hex
16C8 hex
Modbus Mapping
External Register 1
P201
R/W
0000 to FFFF hex
1
16CA
hex
16C9 hex
Modbus Mapping
External Register 2
P202
R/W
0000 to FFFF hex
1
16CB
hex
16CA hex
Modbus Mapping
External Register 3
P203
R/W
0000 to FFFF hex
1
16CC
hex
16CB hex
Modbus Mapping
External Register 4
P204
R/W
0000 to FFFF hex
1
16CD
hex
16CC hex
Modbus Mapping
External Register 5
P205
R/W
0000 to FFFF hex
1
16CE
hex
16CD hex
Modbus Mapping
External Register 6
P206
R/W
0000 to FFFF hex
1
16CF
hex
16CE hex
Modbus Mapping
External Register 7
P207
R/W
0000 to FFFF hex
1
16D0
hex
16CF hex
Modbus Mapping
External Register 8
P208
R/W
0000 to FFFF hex
1
16D1
hex
16D0 hex
Modbus Mapping
External Register 9
P209
R/W
0000 to FFFF hex
1
16D2
hex
16D1 hex
Modbus Mapping
External Register 10
P210
R/W
0000 to FFFF hex
1

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Omron MX2 Series and is the answer not in the manual?

Omron MX2 Series Specifications

General IconGeneral
Cooling MethodFan cooling
Output Frequency Range0.1 to 400 Hz
Control MethodV/f control, Sensorless vector control
Protection FunctionsOvercurrent, overvoltage, undervoltage, overload, overheating, short circuit
Communication OptionsModbus RTU
Overload Capacity150% for 60 seconds
Braking UnitBuilt-in
Ambient Operating Temperature-10°C to +50°C
EnclosureIP20
Storage Temperature-20°C to +65°C
Humidity5 to 95% RH (non-condensing)
AltitudeUp to 1000m
Power Supply Voltage200-240V AC
Input Voltage3-phase 200-240V AC