8 Communications Functions
8 - 100
Multi-function Compact Inverter 3G3MX2-EV2 User’s Manual (I666-E1)
Register
No.
Modbus
register
spec. No
Function name
Parameter
No.
R/W
Monitor or setting data
Data
resolution
Page
2504
hex
2503 hex
2nd Motor Pole
Number Selection
H204
R/W
00: 2P
01: 4P
02: 6P
03: 8P
04 to 23: Do not set 10 to
48P.
P. 6-4
2505
hex
Reserved
2506
hex
2505 hex
2nd Speed
Response
H205
R/W
1 to 1000
1 [%]
P. 6-4
2507
hex
2506 hex
2nd Stabilization
Parameter
H206
R/W
0 to 255
1
P. 7-52
2508
to
2515
hex
Reserved
2516
hex
2515 hex
2nd Motor
Parameter R1
H220
R/W
1 to 65535
0.001
[]
P. 6-9
2517
hex
Reserved
2518
hex
2517 hex
2nd Motor
Parameter R2
H221
R/W
1 to 65535
0.001
[]
P. 6-9
2519
hex
Reserved
251A
hex
2519 hex
2nd Motor
Parameter L
H222
R/W
1 to 65535
0.01
[mH]
P. 6-9
251B
hex
Reserved
251C
hex
251B hex
2nd Motor
Parameter Io
H223
R/W
1 to 65535
0.01 [A]
P. 6-9
251D
hex
251C hex
2nd Motor
Parameter J
H224
(HIGH)
R/W
1 to 9999000
0.001
[kgm
2
]
P. 6-9
251E
hex
251D hex
H224
(LOW)
R/W
251F to
2524
hex
Reserved
2525
hex
2524 hex
2nd Motor
Parameter R1
(Auto-tuning Data)
H230
R/W
1 to 65535
0.001
[]
P. 6-4
2526
hex
Reserved
2527
hex
2526 hex
2nd Motor
Parameter R2
(Auto-tuning Data)
H231
R/W
1 to 65535
0.001
[]
P. 6-4
2528
hex
Reserved
2529
hex
2528 hex
2nd Motor
Parameter L
(Auto-tuning Data)
H232
R/W
1 to 65535
0.01
[mH]
P. 6-4
252A
hex
Reserved
252B
hex
252A hex
2nd Motor
Parameter Io
(Auto-tuning Data)
H233
R/W
1 to 65535
0.01 [A]
P. 6-4
252C
hex
252B hex
2nd Motor
Parameter J
(Auto-tuning Data)
H234
(HIGH)
R/W
1 to 9999000
0.001
[kgm
2
]
P. 6-4
252D
hex
252C hex
H234
(LOW)
R/W
252E to
3102
hex
Not used
Not accessible

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Omron MX2 Series and is the answer not in the manual?

Omron MX2 Series Specifications

General IconGeneral
Cooling MethodFan cooling
Output Frequency Range0.1 to 400 Hz
Control MethodV/f control, Sensorless vector control
Protection FunctionsOvercurrent, overvoltage, undervoltage, overload, overheating, short circuit
Communication OptionsModbus RTU
Overload Capacity150% for 60 seconds
Braking UnitBuilt-in
Ambient Operating Temperature-10°C to +50°C
EnclosureIP20
Storage Temperature-20°C to +65°C
Humidity5 to 95% RH (non-condensing)
AltitudeUp to 1000m
Power Supply Voltage200-240V AC
Input Voltage3-phase 200-240V AC