1 Overview
1 - 32
Multi-function Compact Inverter 3G3MX2-EV2 User’s Manual (I666-E1)
Parameter No.
Function name
A102
OI End Frequency
A103
OI Start Ratio
A104
OI End Ratio
A105
OI Start Selection
A131
Acceleration Curve Parameter
A132
Deceleration Curve Parameter
A141
Calculation Frequency Selection 1
A142
Calculation Frequency Selection 2
A143
Calculation Function Operator Selection
A145
Frequency Addition Amount Setting
A146
Frequency Addition Sign Selection
A154
Deceleration Stop Frequency
A155
Deceleration Stop Time
A156
PID Sleep Operation Level
A157
PID Sleep Operation Delay Time
A161
VR Start Frequency
A162
VR End Frequency
A163
VR Start Ratio
A164
VR End Ratio
A165
VR Start Selection
b001
Power Interruption/Undervoltage Restart Selec-
tion
b002
Allowable Power Interruption Time
b003
Restart Standby Time
b004
Power Interruption/Undervoltage Trip Selection
During Stop
b005
Power Interruption Restart Count
b007
Frequency Pull-in Lower Limit Frequency
b008
Overvoltage/Overcurrent Restart Selection
b010
Overvoltage/Overcurrent Restart Count
b011
Overvoltage/Overcurrent Restart Standby Time
b012
1st Electronic Thermal Level
b212
2nd Electronic Thermal Level
b013
1st Electronic Thermal Characteristics Selection
b213
2nd Electronic Thermal Characteristics Selection
b015
Free-electronic Thermal Frequency 1
b016
Free-electronic Thermal Current 1
b017
Free-electronic Thermal Frequency 2
b018
Free-electronic Thermal Current 2
b019
Free-electronic Thermal Frequency 3
b020
Free-electronic Thermal Current 3
b021
1st Overload Limit Selection
b221
2nd Overload Limit Selection
b022
1st Overload Limit Level
b222
2nd Overload Limit Level
b023
1st Overload Limit Parameter
b223
2nd Overload Limit Parameter
b024
1st Overload Limit Selection 2
b025
1st Overload Limit Level 2
b026
1st Overload Limit Parameter 2
b027
Overcurrent Suppression Selection
b028
Frequency Pull-in Restart Level
b029
Frequency Pull-in Restart Parameter

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Omron MX2 Series and is the answer not in the manual?

Omron MX2 Series Specifications

General IconGeneral
Cooling MethodFan cooling
Output Frequency Range0.1 to 400 Hz
Control MethodV/f control, Sensorless vector control
Protection FunctionsOvercurrent, overvoltage, undervoltage, overload, overheating, short circuit
Communication OptionsModbus RTU
Overload Capacity150% for 60 seconds
Braking UnitBuilt-in
Ambient Operating Temperature-10°C to +50°C
EnclosureIP20
Storage Temperature-20°C to +65°C
Humidity5 to 95% RH (non-condensing)
AltitudeUp to 1000m
Power Supply Voltage200-240V AC
Input Voltage3-phase 200-240V AC