9
TRSM(45) TRACE MEMOR
Y SAMPLE
MCRO(99) MACRO
MAX(--) FIND MAXIMUM
MIN(--) FIND MINIMUM
SUM(--) SUM
SRCH(--) DAT
A SEARCH
FPD(--) FAILURE POINT DETECTION
PID(--) PID CONTROL
HEX(--) ASCII T
O HEX
XDMR(--) EXP
ANSION DM READ
DSW(--) DIGITAL SWITCH INPUT
TKY(--)
TEN-KEY INPUT
MTR(--) MATRIX INPUT
HKY(--)
16-KEY INPUT
ADBL(--)
DOUBLE BINAR
Y ADD
SBBL(--)
DOUBLE BINAR
Y SUBTRACT
MBSL(--)
DOUBLE SIGNED BINAR
Y MULTIPL
Y
DBSL(--)
DOUBLE SIGNED BINAR
Y DIVIDE
MBS(--)
SIGNED BINAR
Y MULTIPL
Y
DBS(--)
SIGNED BINAR
Y DIVIDE
FCS(--)
FRAME CHECKSUM
7SEG(--)
7-SEGMENT DISPLA
Y OUTPUT
RXD(--) RECEIVE
TXD(--) TRANSMIT
CPS(--)
SIGNED BINAR
Y COMP
ARE
CPSL(--)
SIGNED DOUBLE
BINAR
Y COMP
ARE
NEG(--) 2’S COMPLEMENT
NEGL(--) DOUBLE 2’S COMPLEMENT
ZCPL(--)
DOUBLE AREA RANGE COMP
ARE
AVG(--) A
VERAGE V
ALUE
SCL(--) SCALE
SET SET
RSET RESET
TTIM(87) TOTALIZING TIMER
XFRB(62)
TRANSFER BITS
ZCP(88)
AREA RANGE COMP
ARE
1-8-4 Wide Selection of Special I/O Units
C200HS
Systems can be configured in a variety of ways, using High-density
I/O
Units, High-speed Counters, Position Control Units, Analog I/O Units, T
empera-
ture Sensor Units, ASCII Units, V
oice Units, ID Sensor
Units,
Fuzzy Logic Units,
Cam Positioner Units, and so on.
1-8-5 Improved Interrupt Functions
Scheduled Interrupts The
C200HS’
s scheduled interrupt function
has been improved so that the inter
-
rupt
interval can be set in 1
ms units rather than the 10 ms units in the C200H.
When
the interrupt mode is
set to C200HS mode, the interrupt response time is
only 1 ms max. (excluding the input
ON/OFF delays). When a Communications
Unit
is used with the C200HS-CPU31-E/CPU33-E CPU, the interrupt response
time is 10 ms max.
Input Interrupts Up
to 8 interrupt subroutines
can be executed by inputs to a C200HS-INT01 In
-
terrupt Input Unit mounted to the C200HS. When the interrupt mode is set to
C200HS
mode, the interrupt response time is only 1 ms max. (excluding the in
-
put ON/OFF delays). When a Communications Unit is used with the C200HS-
CPU31-E/CPU33-E CPU, the interrupt response time is 10 ms max.
1-8-6 SYSMAC NET Link and SYSMAC LINK Capabilities
The SYSMAC NET Link and SYSMAC LINK Systems are high-speed FA net-
works which can be used with the C200HS-CPU31-E and C200HS-CPU33-E
CPUs and the following Units:
SYSMAC NET Link Unit: C200HS-SNT32
SYSMAC LINK Units:
C200HS-SLK12 (optical fiber cable)
C200HS-SLK22 (coaxial cable)
Data
can be exchanged with the PCs in a SYSMAC NET Link or SYSMAC LINK
System using the SEND and RECV instructions.
New C200HS Features Section 1-8