229
In the case below, 1,799,100,099 – (–282,751,929) = 2,081,851,958
(6B3C 167D – {EF25 8C47 – 1 0000 0000} = 7C16 8A36). Neither OF nor UF
are turned ON.
Au
+ 1 : 001
Au : 000
Ad + 1 : DM 0021
Ad : DM 0020
6B3C 167D
EF25
8C47
0
–
R + 1 : LR 22
R : LR 21
8A367C16
0
CY (Cleared with CLC(41))
UF (SR 25405)
0
OF (SR 25404)
–
Note The
status of the CY flag can be ignored when adding signed binary data since it
is relevant only in the addition of normal hexadecimal values.
5-20-7 SIGNED BINARY MULTIPLY – MBS(––)
Md: Multiplicand word
IR, SR, AR, DM, HR, TC, LR, #
Mr: Multiplier word
IR, SR, AR, DM, HR, TC, LR, #
Ladder Symbols
Operand Data Areas
R: First result word
IR, SR, AR, DM, HR LR
MBS(––)
Md
Mr
R
@MBS(––)
Md
Mr
R
Limitations R and R+1 must be in the same data area.
Description MBS(––) multiplies the signed binary content of two words and outputs the
8-digit
signed binary result to R+1 and R. The rightmost four digits
of the result
are
placed in R, and the leftmost four digits are placed in R+1. Refer to page
29
for details on signed binary data.
Md
Mr
R
+1
R
X
Flags ER: Indirectly
addressed
DM word is non-existent. (Content of
:
DM word is
not BCD, or the DM area boundary has been exceeded.)
EQ: ON when the result is 0000 0000, otherwise OFF.
Binary Calculations Section 5-20

Table of Contents

Other manuals for Omron SYSMAC C200HS

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Omron SYSMAC C200HS and is the answer not in the manual?

Omron SYSMAC C200HS Specifications

General IconGeneral
BrandOmron
ModelSYSMAC C200HS
CategoryController
LanguageEnglish

Related product manuals