4. Return the server to operation.
a. Install the server top cover.
See Install the Server Top Cover.
b. Return the server to the normal rack position.
See Return the Server to the Normal Rack Position.
c. Reconnect the power cords to the server power supplies, and power on the server.
See Powering On Oracle Database Appliance.
d. Verify that the power supply AC OK LED is lit.
Servicing the PCIe Slot Flyover Cable (FRU)
Perform tasks in this section to service the PCIe Slot Flyover Cable.
• Remove the PCIe Flyover Cable
• Install the PCIe Flyover Cable
Remove the PCIe Flyover Cable
The PCIe Flyover cable is required to provide x16 functionality to PCIe slot 6. The Oracle
Database Appliance X10-S and X10-L include a PCIe retimer card in slot 6 that is used for
front-mounted NVMe SSD storage.
Note:
The use of PCIe slot 7 is not supported for this product.
1. Prepare the server for service.
Chapter 5
Servicing the PCIe Slot Flyover Cable (FRU)
5-37