9.1 PWM output function
9.1.1 Overview of PWM Output Function
The pulse output of an arbitrary duty ratio can be performed.
Comparison of functions and performances
Channel no.
Transistor output type Relay output type
Output no.
Control active
flag
Output no.
Control active
flag
Installation position
CH0 Y0 R911C Y100 R911C
Cassette mounting
part 1
CH1 Y2 R911D Y200 R911D
Cassette mounting
part 2
CH2 Y4 R911E - -
CH3 Y6 R911F - -
(Note 1) Functions, channel numbers and I/O numbers used are set in the tool software.
(Note 2) I/O numbers used for each function should be allocated so that they do not overlap.
9.1.2 System Register Settings
Functions to be used are allocated in the "System register settings" dialog box. The following
procedure is explained on the condition that the FPWIN GR7 has already started.
1. Select Options>System register settings from the menu bar.
The "PLC Configuration" dialog box appears.
2. Select "Controller output setting (PLS / PWM)" from the left pane.
The setting menu for the system register “No. 402" appears.