For the E-point control, enter settings in one row.
For P-point, C-point and J-point controls, they should be combined with E-point control of the
next step as a pair and the setting should be input in two rows.
When E: End point is not selected in the next row of P: Pass point, C: Continuance point or J:
Speed point, the self-diagnostic error (error code 44: positioning error) is detected.
Settings of J-point control
For J-point control, only "Increment" can be selected as a control method.
For changing speed during J-point control, set the target speed after the change in the
positioning parameter dialog box.
5.4.2 E-point Control (Single-Speed Positioning)
The parameters for position control operations are specified in the positioning parameter
setting menus and data tables of Configurator PMX.
When the positioning table start instruction (F380 POSST) or positioning simultaneous start
instruction (F383 MPOST) is executed, the pulse output will start and the positioning control
operation will be performed.
Operation diagram
t [ms]
f [Hz]
100ms
200ms
50ms
100,000 pulses
20,000Hz
1,000Hz
Instruction
start condition
Busy signal
Operation
done signal
Table 1