11.2 Allocation of Memory Areas
11.2.1 When Using Pulse Output Table Setting Mode
■
Control unit (transistor output type)
Channel no.
Input / output contact number used Memory area
used
CW
or
Pulse
output
CCW
or
Sign
output
Deviation counter
clear output
Hom
e
input
(Note
1)
Near
home
input
(Note 2)
Over
limit
input
(Note
3)
J-
point
positi
oning
start
input
BUSY
flag
Elapse
d
value
area
C14 C30 C60
Independent
CH0 Y0 Y1 Y4 Y8 YC X4 (Y70)
(Y80)
(Y81)
X0 X28
(Note 4)
CH1 Y2 Y3 Y5 Y9 YD X5 (Y71)
(Y82)
(Y83)
X1 X29
CH2 Y4 Y5 - YA Y10 X6 (Y72)
(Y84)
(Y85)
- X2A
CH3 Y6 Y7 - YB Y11 X7 (Y73)
(Y86)
(Y87)
- X2B
CH4 Y8 Y9 - - Y12 X2 (Y74)
(Y88)
(Y89)
- X2C
CH5 YA YB - - Y13 X3 (Y75)
(Y8A)
(Y8B)
- X2D
Linear interpolation
(Note 1)
CH0
X-
axis
Y0 Y1 Y4 Y8 YC X4 (Y70)
(Y80)
(Y81)
-
X28
(Note 4)
Y-
axis
Y2 Y3 Y5 Y9 YD X5 (Y71)
(Y82)
(Y83)
X29
CH2
X-
axis
Y4 Y5 - YA Y10 X6 (Y72)
(Y84)
(Y85)
X2A
Y-
axis
Y6 Y7 - YB Y11 X7 (Y73)
(Y86)
(Y87)
X2B
CH4
X-
axis
Y8 Y9 - - Y12 X2 (Y74)
(Y88)
(Y89)
X2C
Y-
axis
YA YB - - Y13 X3 (Y75)
(Y8A)
(Y8B)
X2D
(Note 1) Even when setting the linear interpolation, the interpolation operation is not performed for the home
return. Execute the operation for X axes and Y axes separately.
(Note 2) The near home input will be valid when arbitrary inputs are allocated and the output relays indicated in
the above table turn ON.
(Note 3) The over limit input (+) and over limit input (-) will be valid when arbitrary inputs are allocated and the
output relays indicated in the above table turn ON. The I/O numbers in the upper rows (Y80 to Y8A) in
the above table are over limit input (+), the I/O numbers in the lower rows (Y81 to Y8B) are over limit
input (-).
11.2 Allocation of Memory Areas
WUME-FPXHPOSG-01 11-5