(Note 2) The emergency stop will be enabled by specifying channel numbers and turning ON the bit 3 of the
special data register DT90052 by the pulse output control instruction (F0). In case of the emergency
stop in the FP-X compatible instruction mode, pulses stop immediately.
Allocation of I/O relating to pulse output control (Only in FP-X compatible
instruction mode)
By using the special data register DT90052 by the pulse output control instruction (F0),
operations such as loading the near home input and stopping the pulse output forcibly can
be performed.
When controlling the above functions using external inputs, arbitrary inputs can be allocated.
The following program is for loading the near home input of CH1 using the input X10.
In the FP-X compatible instruction mode, the allocations of J-point control and over limit inputs
are not available.
In the FP-X compatible instruction mode, the allocations of system stop, error clear request,
deceleration stop and J-point speed change are not available.
4.1.3 When Using PWM Output Function
The following reserved areas are allocated to the PWM output or control active flag.
Allocate them so that they do not overlap the I/O used for the pulse output function.