Code Value Description
(f)
Target value 3: ON set
value
(g)
Target value 2: ON set
value
(h)
Target value 1: ON set
value
(1) Execution condition
When the execution condition turns ON from OFF, the instruction is executed
and the cam control starts.
(2)
High-speed counter
instruction
active flag
The high-speed counter instruction active flag turns ON during the execution
of the instruction.
(3) Cam output The output turns ON/OFF according the set values.
(4)
Interrupt program
activation
In the case of subtraction, when the elapsed value falls below the OFF set
value, the interrupt program is started.
■
Sample program
Code Description
(1) High-speed counter channel H10: Performs the upper limit control, CH0
(2) Cam output device type K1: Internal relay (R)
(3) Word number of cam output device K10
(4) Specification of the number of target values K3
(5) Target value 1: ON set value K1000
(6) Target value 1: OFF set value K7000
(7) Target value 2: ON set value K3000
10.4 High-speed Counter Cam Control Instruction
WUME-FPXHPOSG-01 10-29