Code Value Description
(f)
Target value 3: ON set
value
(g)
Target value 2: ON set
value
(h)
Target value 1: ON set
value
(1) Execution condition
When the execution condition turns ON from OFF, the instruction is executed
and the cam control starts.
(2)
High-speed counter
instruction
active flag
The high-speed counter instruction active flag turns ON during the execution
of the instruction.
(3) Cam output The output turns ON/OFF according the set values.
(4)
Interrupt program
activation
In the case of subtraction, when the elapsed value falls below the OFF set
value, the interrupt program is started.
Sample program
Code Description
(1) High-speed counter channel H10: Performs the upper limit control, CH0
(2) Cam output device type K1: Internal relay (R)
(3) Word number of cam output device K10
(4) Specification of the number of target values K3
(5) Target value 1: ON set value K1000
(6) Target value 1: OFF set value K7000
(7) Target value 2: ON set value K3000
10.4 High-speed Counter Cam Control Instruction
WUME-FPXHPOSG-01 10-29